Superior Sensitivity in Refrigerant Leak Detection
As sensitive as it is tough.
State of the art infrared sensor
Sensitivity better than 0.1 oz/yr
CFC, HFC, HCFC and blends
Auto recalibration
Senses refrigerant level change
Works in contaminated areas
Infrared Refrigerant Leak Detector for HVACR - Superior Sensitivity in a Rugged Design for HVACR
Like all of Fieldpiece's test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. We set out to develop the best refrigerant leak detector for HVACR. We believe the SRL2 is it. It comes in kit form in a rugged, blow-mold case with all of the extras (see What's Included tab).
The ergonomic design fits naturally in your hand. The ruggedized construction stands up to abuse most other leak detectors can't handle. The eight-hour battery life lets you work all day before recharging and the included vehicle and wall chargers help you during overtime. The mute and peak functions allow you to work the way you want to work. The magnetic hanger helps keep the detector out of the way when repairing a leak, but visible enough so you won't leave it on the job.
Advantages Over Other Types of Refrigerant Leak Detectors
Triggers on all CFCs, HFCs, HCFCs and blends.
Sealed sensor. Unlike heated diode and corona discharge leak detectors, the sensor doesn't "touch" refrigerant as it passes through the instrument. Heated diode and corona discharge units tend to degrade or fail when they come in contact with high concentrations of refrigerant or touch liquid.
Doesn't trigger on oil or moisture like other types of detectors.
Senses change in refrigerant levels. Works even in contaminated environments.
Up and running in less than 30 seconds. Some heated elements and corona discharge units take much longer to warm up. UV dyes can take several hours to travel through a running system and can degrade system components.
Designed for HVACR
Superior - Controlled Sensitivity. Doesn't trigger on nuisance leaks unless in Turbo Mode.
Rugged / Ergonomic Features. Ruggedized boot and it fit's in your hand.
Infrared Sensor. Lasts up to 10 years.
Three Sensitivity Levels. Meets new SAE standards.
Audible/Visual Alarm. Turn the beep on or off - you decide.
8-hour Battery Charge. Work all day on one charge.
Non-conductive, Sturdy Probe. Stays where you want it.
Peak / Mute Buttons. Find leaks in noisy environments.
Magnetic Hanger. Hang the unit while you repair the leak.
Weighs 14-oz. Tough doesn't have to mean heavy.
What's Included
Advanced Refrigerant Leak Detector - SRL2(K7)
(5) O-rings and 10 Replacement Filters - RFL2
9-inch Flex-Probe Extension - RFE2
Rigid Extension Probe - RRE2
Blow-Molded Case - ABMK3
Operator’s Manual
Specifications
Sensing element: Enhanced infrared photo optics
Sensor life: 10 years
Refrigerants: HFC, CFC, HCFC, and blends
Sensitivity: Min (Stationary): 0.1oz/yr (3g/yr)
Response time: 1 second
Recovery time: ~4 seconds
Auto off: 10 minutes after no activity
Battery: 3.7VDC(nominal), rechargeable lithium ion user-replaceable battery
Battery life: 8 hours continuous use prior to needing a charge. Degradation (30%) after 500 charge/discharge cycles or two years, whichever comes first
Low battery LED: Lights when approximately 1 hour of battery life remains
Charge time: Less than 4 hours (either charger)
Operating environment: 32ºF (0°C) to 104ºF (40°C) at <75%RH (non-condensing)
Storage environment: <80%RH meter and battery