14/18L Dental Medical Steam Autoclave Sterilizer Sterilization/Drying Function S
$ 279.31
- Description
- Size Guide
Description
TR250NM-1, 18L Steam Sterilizer Description:Chamber capacity:Ø25×D35CM (Ø9.84×D13.78inch)
Inside capacity
:
18 Liter
Material
:
Stainless steel #304
Outside Size(L*W*H)
:
58*39*36 CM
Packing Size(L*W*H)
:
64*44*36.5CM
Sterilizer temperature/pressure
:
121℃/0.12Mpa; 134℃/0.22Mpa
Sterilize time
:
25Min/6Min
Power
:
900W
AC110V/8A
AC220V/4A
SAFETY : Heating-over protection ; safety valve
Safety equipment:
1.Pressure adjustment: adjust the inter pressure, if over standard value
automatic vent
2.
Avoid overheat protect device: when inter temperature overheat, power break electric current automatically.
Temp and Press display :Led several windows
Disinfection principle
:
Uses the vapor power emissions cold air / 2 times
Caution
:
1.Before each use, distilled water is better .
2.Do not use any corrosive or chemical water as the disinfection.
3.Do not share the same electricoutllet with other electrical apparetus.
4.Please pay attention to correct voltage and frequency.
5.Connect steam exhaust pipe with the steam vent
,
before operation.
Packing:
main unit 1pc
Standard accessories:
Tray Rack 1pc
Tray 3pcs
Tray removal tong 1pc
Draining Tube 1pc
Intake pipe 1pc
Operation manual 1pc
Power cord 1pc
Filter core 2pcs
TR250E, 14L Steam Sterilizer Description:
Chamber capacity:Ø25×
D
28CM (Ø9.84×D11.02inch)
Inside capacity:14 Liter
Material:Stainless steel #304
Outside Size :46.5*35*36 CM
Packing Size :51*39*40 CM
G.W:15KGS
Sterilizer temperature:121℃
Sterilize pressure:0.12Mpa
Sterilize time:25Min
Power:900W
AC110V
/8A
AC220V
/4A
Auto supply water
system: Manual
give the water
Safety valve: automatic discharge in excess of standard value
Temp and Press display:Pressure gauge
Disinfection
principle
:Uses the vapor power emissions cold air / 2 times
Operation Steps:
1.Plug in the power cord
2.Shut exhaust needle valve in the Close (clockwise)°
3.Adding about 800 ml of distilled water. Close the door
cover, tight
the rotate handle
4. Start the timer knob to 121 ℃ position. Sterilization is working.
5.Sterilization is complete, please be sure to open the exhaust needle valve firstly (inverse clock direction)
6.Wait for the pressure gauge pointer to zero, opened the door cover
Caution:
Every time sterilization, must add about 800 ml of distilled water
Use a separate socket (confirm the socket of the output voltage)
Pressure gauge pointer in the red areas, please be sure to first Open the exhaust steam of the needle valve
Packing:
main unit
1pc
Standard accessories:
Plate 3pcs ( Size:2
1
*
15.5
*2
c
m)
Shelf 1pc
Take Plate tool 1pc steam exhaust pipe 1pc(1 meter length)